I-10KW DC ukuya kwi-AC Inverter Grid-Tied Solar System
Ingcaciso yeMveliso
| Max.I-DC yesekethe emfutshane yangoku | 40 A (20 A / 20 A) |
| Imveliso (AC) | |
| Ilinganiswe amandla emveliso ye-AC | 5000 W. 10000 W |
| Max.AC Imveliso amandla | 5000 VA.10000 VA |
| Ilinganiswe kwimveliso ye-AC yangoku (kwi-230 V) | 21.8 A 43.6A |
| Max.Imveliso ye-AC yangoku | 22.8 A 43.6A |
| Umlinganiselo wombane we-AC | 220 / 230 / 240 V |
| Uluhlu lwamandla ombane we-AC | 154 - 276 V |
| Ireyithwe ngamaza egridi / uluhlu lwamaza egridi | 50Hz / 45 – 55Hz, 60Hz / 55 – 65Hz |
| IHarmonic (THD) | < 3 % (ngamandla alinganisiweyo) |
| Imeko yamandla kumandla okalisiweyo / into yamandla ehlengahlengiswayo | > 0.99 / 0.8 ehamba phambili - 0.8 lagging |
| Izigaba zokuphakela / izigaba zoqhagamshelo | 1/1 |
| Ukusebenza kakuhle | |
| Max.ukusebenza kakuhle | 97.90% |
| Ukusebenza kakuhle kweYurophu | 97.3 % 97.5 % |
| Ukhuseleko | |
| Ukujongwa kwegridi | Ewe |
| Ukhuseleko lwe-polarity umva lwe-DC | Ewe |
| I-AC yokukhusela i-short-circuit | Ewe |
| Ukhuseleko lwangoku lokuvuza | Ewe |
| UKhuseleko lweSurgery | DC typeII/ACtypeII |
| Ukutshintsha kwe-DC | Ewe |
| PV umtya esweni ngoku | Ewe |
| I-Arc fault circuit interrupter (AFCI) | Ukhetho |
| Umsebenzi wokubuyisela i-PID | Ewe |
| Idatha ngokubanzi | |
| Imilinganiselo (W*H*D) | 410 * 270* 150 mm |
| Ubunzima | 10 kg |
| Indlela yokukhwela | Isibiyeli esifakwa eludongeni |
| I-Topology | Transformerless |
| Umgangatho wokhuseleko | IP65 |
| Uluhlu lweqondo lobushushu elisebenzayo | -25 ukuya kuma-60 °C |
| Uluhlu oluvumelekileyo lokufuma (alunciphisi) | 0 - 100 % |
| Indlela yokupholisa | Ukupholisa kwendalo |
| Max.ubude bokusebenza | 4000 m |
| Bonisa | Umboniso wedijithali we-LED kunye nesalathisi se-LED |
| Unxibelelwano | I-Ethernet / WLAN / RS485 / DI (Ulawulo lweRipple & DRM) |
| DC uhlobo loqhagamshelwano | MC4 (Ubukhulu. 6 mm2) |
| Uhlobo loqhagamshelwano lwe-AC | Iplagi kwaye udlale isinxibelelanisi (Ubukhulu 6 mm2) |
| Ukuthotyelwa kwegridi | IEC/EN62109-1/2, IEC/EN62116, IEC/EN61727, IEC/EN61000-6-2/3, EN50549-1, AS4777.2, ABNT NBR 16149, ABNT NBR 16150, UNE002 NTS27 , CEI 0-21:2019, VDE0126-1-1/A1 (VFR-2019), UTE C15-712, C10/11, G98/G99 |
| Inkxaso yegridi | Ulawulo lwamandla olusebenzayo nolusebenzayo kunye nolawulo lwerempu yamandla |
ISIVUNO ESIPHEZULU
Iyahambelana neemodyuli zePV zamandla aphezulu kunye neemodyuli ze-bifacial
Ukuqalisa okusezantsi kunye noluhlu olubanzi lwe-MPPT yamandla ombane Owakhelwe ngaphakathi kwi-PID ehlakaniphile yokubuyisela umsebenzi
UKUSETYENZISWA KOBUHLOBO
Iplagi kwaye udlale ufakelo
Ukukhanya kunye nokudibanisa kunye noyilo oluchanekileyo lokutshatyalaliswa kobushushu
IKHUSELEKILEYO KWAYE INENEMBEKO
I-arc fault edityanisiweyo yesiphazamisi sesekethe eyakhelwe-ngaphakathi Uhlobo lwe-II DC & AC SPD
Ireyithingi yokukhusela ukubola kwi-C5
ULAWULO NGOBULUMKO
Idatha yexesha langempela (imizuzwana eyi-10 yokuhlaziya isampula) 24/7 esweni ephilayo zombini kwi-intanethi kunye nomboniso odibeneyo
Kwi-Intanethi IV ijika scan kunye nokuxilongwa
Yintoni i-On-grid Inverter
Kukho iindidi ezimbini zombane.Kukho i-AC kwaye kukho i-DC.I-inverter ye-on-grid isetyenziselwa ukuguqula i-DC okanye i-current ngqo ibe yi-AC alternating current.Izixhobo zombane emakhayeni ethu ziyilelwe ukuba ziphume kubonelelo lwe-AC kwaye zizifumana kwizikhululo zombane ezibonelela ngombane we-AC.Nangona kunjalo umbane oveliswa ngumbane welanga kunye neebhetri zivelisa umbane we-DC, ke ukuba abasebenzisi bafuna ukunika amandla izixhobo zakho zombane kwimithombo evuselelekayo okanye kwiibhanki zebhetri, kufuneka baguqule umbane we-DC kumbane we-AC, kwaye kungenxa yoko ii-inverters ziyimfuneko kwi-renewable. izisombululo zamandla..
Zisebenza njani ii-On-grid Inverters
I-inverter inenani lokutshintsha kwe-elektroniki okwaziwa ngokuba zii-IGBTs.Ukuvulwa nokuvalwa kokutshintsha kulawulwa ngumlawuli.Ziyakwazi ukuvula nokuvala ngokukhawuleza okukhulu ngababini ukulawula ukuhamba kombane ngokulawula indlela ohamba ngayo umbane kunye nokuba uhamba ixesha elide kangakanani kwiindlela ezahlukeneyo.Inokuvelisa umbane we-AC ukusuka kumthombo we-DC.Inokusebenzisa umlawuli ukwenza oku ngokuzenzekelayo kwakhona kwaye kwakhona kwaye kwakhona.ukuba iyatshintsha amaxesha angama-120 ngesekhondi kuya kufumaneka umbane we-60 Hertz;kwaye ukuba iyatshintsha loo 100 amaxesha ngomzuzwana kwaye uya kufumana 50 Hertz umbane.
Kumazwe amaninzi, amakhaya okanye iinkampani ezine-on-grid inverter systems zinokuphinda zithengise umbane eziwuvelisayo kwinkampani yamandla.Kukho iindlela ezininzi ezahlukeneyo zokufumana inkxaso-mali ukuba umbane ubuyiselwa kwigridi.Amakhaya okanye iinkampani ezinezixhobo zamandla ahlaziyekayo zifumana uncediso-mali olusekwe kumandla ombane abawathumelayo kwigridi.Sinokubala nje ukuba ungakanani umbane onokuthi ugcinwe ngumbane kwindlu ngonyaka.Amandla amakhulu DC ukuya kwi-AC Inverter Grid-Tied Solar System idlala indima ebalulekileyo kwinkcitho yendlu.Inkcitho eyongezelelweyo esiyongayo kumbane inokushukunyiswa kwimfundo nobomi.